Journal of Endodontics Research - http://endodonticsjournal.com
A comparison of the shaping characteristics of two nickel–titanium endodontic hand instruments
http://endodonticsjournal.com/articles/34/1/A-comparison-of-the-shaping-characteristics-of-two-nickelatitanium-endodontic-hand-instruments/Page1.html
By JofER editor
Published on 03/20/2002
 

C. Dobo-Nagy, T. Serban, J. Szabo, G. Nagy  & M. Madlena
Department of Prosthetic Dentistry, Faculty of Dentistry, Semmelweis University, Budapest, Hungary.
Dental School, Medical University of Pecs, Pecs, Hungary.

Aim.
The purpose of this study was to compare the shaping characteristics of Ni–Ti K-files and Ni–Ti S-files manipulated by hand.

Conclusions.
Under the conditions of this study, preparation with Ni–Ti K-files produced more appropriate shapes in roots with apically curved canals than Ni–Ti S-files.


Introduction - Materials and methods.

C. Dobo-Nagy, T. Serban, J. Szabo, G. Nagy  & M. Madlena
Department of Prosthetic Dentistry, Faculty of Dentistry, Semmelweis University, Budapest, Hungary.
Dental School, Medical University of Pecs, Pecs, Hungary.

Introduction.
Cleaning and shaping of root canals is the most important aspect of root canal treatment. Over the years, a number of instruments have been developed for shaping canals. In previous studies (Dobo-Nagy et al. 1997a,b), statistically significant differences were found when comparing the shaping ability of stainless steel K-files and K-Flex files. Post-instrumentation shape of curved canals was superior when prepared with flexible stainless steel instruments than with conventional files (Briseno & Sonnabend 1991, Al-Omari et al. 1992). However, increasing the flexibility of endodontic instruments through the use of Ni–Ti alloy has not always resulted in better shaping ability (Gambill et al. 1996, Harlan et al. 1996, Elliott et al. 1998, Carvalho et al. 1999).
The Ni–Ti S hand file is made by grinding a circular tapered blank into a double helix fluted pattern. The helical angle is closer to an H-file than a K-file and this may explain the improved cutting efficacy of S-files in linear motion (Schafer 1997). Shaping ability of stainless steel files was tested in resin blocks (Briseno & Sonnabend 1991) but no statistically significant differences between the nine instruments were found. However, when taking the ideal values as reference points, statistical differences were found in canals enlarged with S-files at all the three measured levels. In addition, the S-file provided poorer results compared with the H-file at the apical level (1 mm coronally from the end-point) and at the third measured point (11.5 mm coronally). The S-file showed an increased tendency to transport root canals toward the convex side at the apical level and toward the concave side at the middle level, when compared to stainless steel, a K-file or a K-Flex file. To date, no investigation of the shaping quality of Ni–Ti S hand files has been reported.
The aim of this study was to compare the shaping characteristics of the two nickel–titanium instruments in extracted human root canals.

Materials and methods.
A total of 153 extracted human teeth with a single canal and patent apical foramen were selected. The specimens had been stored in phosphate buffer saline solution (pH 7.2) containing sodium azide 0.2% at 4 C. Each root was embedded in a 15 15 20 mm resin block. Access cavities were cut just into the dentine using a high-speed bur. The roof of the pulp chamber was then removed with a slowly rotating round bur. Following pulp extirpation, the root canals were filled with a radiopaque mixture of Lipiodol Ultra-Fluid (Byk, Konstanz, Germany) and Micropaque HD Oral (Guerbet, Schultzbach, Germany) by centrifuging at 1200 g for 30 s. An initial size 15 apical file (IAF) was inserted into the canals and digitized radiographs (RVG, Trophy Radiologie, Paris, France) were taken from bucco-lingual (b-l) and mesio-distal (m-d) directions using a paralleling technique (Forsberg 1992). Dilacerated, bayonet-shaped and extremely narrow canals that could not be penetrated by a file size 10 were excluded. Roots were divided into three groups on the basis of their radiographic images using computergraphic software (Dobo-Nagy et al. 1995). The roots were grouped according to canal shape, namely: straight (I-form), apically curved ( J-form) and continuously curved (C-form). Each group (containing 20 roots) was divided randomly into two equal subgroups for preparation using one of the following two instrument types: (i) Ni–Ti K-file (Beutelrock, München, Germany); (ii) Ni–Ti S-file (Sendoline, Kista, Sweden). Root canal enlargement was carried out randomly by two operators with considerable experience in root canal preparation. The process was carried out with purely tactile sensation, however, the working length and the b-l and m-d configuration of each canal was always available to the operator. The root length was modified by sectioning the coronal end in order to obtain a working length of 18 2 mm. Apical limit was determined 1 mm coronal to the radiographic apex. Files were used in a push–pull motion around the entire circumference of the canal. The step-back preparation technique was adopted for both instruments (Mullaney 1979). Preflaring of orifices was not carried out. The IAF was size 15, the master apical size was 30 and the root canal flared using a size 40 file. Copious irrigation with 10 mL distilled water was used throughout the preparation and was introduced with a 27-gauge needle and a syringe. Two postoperative radiographs were taken of each root using radiovisiography as described previously.

Canal defects.
The apical limit of the root canal preparation located within 1 mm of the radiographic apex was termed the apical stop . The creation of a false channel that exited the root surface during instrumentation at a point other than the anatomic apical foramen was termed a perforation . A zip was defined as an irregular and excessive widening of the canal close to the end-point of the preparation. The narrowest level of the apical third of the canal associated with zip which occurred more toward the orifice was termed the elbow . In the middle part of the canal, excessive removal of dentine from the inner aspect of canal curves was termed the danger zone . Coronal movement of the apical stop and loss of working length due to a buildup of dentine mud was termed a blockage .

Assessment of canal preparation.
The time taken to prepare each canal was recorded in min and s. It included the preparation, as well as changing files, and irrigation time.
Superimposed, standardized 1 : 10 projections of the original canal and the prepared canal in mesio-distal and bucco-lingual directions were used to evaluate the difference in shape between pre- and postoperative canals. Accurate location and superimposition of the radiographs in both views was facilitated by the presence of two metal markers placed at the corners of one side of each resin block.
The prevalence of perforations, blockages, zip and elbow formation were noted. The amount of dentine removed at the most coronal level of the canal was determined and the surface area at this level obtained by calculating the area of an ellipse ( ab). Lateral projections of the elliptic surface were gained by the two directional radiographs. The radii of the ellipse (a and b) were determined by dividing the measured diameters of the canal at this level of the two views (b-l and m-d), respectively.
Canal transportation was expressed by the maximum asymmetry of preparation. The maximum asymmetry of preparation at the apical level and at the danger zone of the root canals was measured on the inner concave and the outer convex sides. Measurements were carried out perpendicular to the axis of the original canal using the method of Dobo-Nagy et al. (1997b). The original canal width was divided into two halves, thus defining a point of the canal axis which served as a reference point for the measurement of asymmetry. Asymmetry (expressed as an absolute value) was calculated by subtracting the left from the right prepared canal contour distances from the reference point.

Statistical analysis.
Analysis of covariance was used to compare the preparation time, the amount of removed material at the most coronal part of canals and root canal form groups. Duncan’s multiple range test was used for statistical analysis of the asymmetry of preparation values. Significant differences were noted at P < 0.05 level.


Results.

Procedural accidents.
No perforations occurred in the canals of any groups.
Coronal movement of the apical stop was not dependent on the instrument type but it was more frequently observed in curved canals. In canals prepared with Ni–Ti S-files two straight, four J-form and four C-form canals were affected. In the Ni–Ti K-file group two straight, four J-form and two C-form canals had reduced working length following instrumentation. The mean distance between the apical stop and apex was 0.34 mm in the Ni–Ti K-file group and 0.32 mm in the Ni–Ti S-file group; this difference was not significant.

Zips and elbows.
The prevalence of zips and elbows was 26.6% in both groups. The mean width of the elbow was 0.36 mm. The mean elbow to root apex distance was 1.68 mm. In the Ni–Ti K-file group an elbow occurred in one of the straight canals, two of the J-forms and five of the C-form canals. In the Ni–Ti S-file group elbows were detected in two of the straight canals, five of the J-form and one of the C-form canals.

Preparation time.
There was no statistically significant difference in preparation times between the instruments (Table 1)..

Table 1. Mean preparation time (min) and area change (mm2) at the most coronal level grouped by file and canal form.

Mean preparation time (min) and area change at the most coronal level grouped by file and canal form
I, straight root canal;
J, apically curved canal;
C, continuously curved canal.

Area change at the orifice.
The results of area change measurements at the most coronal level are presented in Table 1. Statistical analysis revealed that Ni–Ti S-files removed significantly greater amounts of dentine compared to Ni–Ti K-files ( P < 0.05). The analysis of covariance did not show any statistically significant relationships between the amount of removed dentine at the most coronal level and the preparation time.

Canal transportation at the apical level.
Mean transportation values at the apical level are outlined in Figure 1. In the case of straight and C-form canals there were no significant difference between the two instruments. Significantly less transportation was obtained from the Ni–Ti K-file in J-form canals compared to Ni–Ti S-file in the same anatomical group ( P < 0.05). Ni– Ti S-file produced less transportation on the C-form canals compared to the J-form canals, however, this difference was statistically significant only in the proximal view ( P < 0.05). The Ni–Ti K-files were not significantly different in the J-form and C-form groups.

Figure 1. Mean preparation asymmetry values at the apical level representing both clinical and proximal views parameters.

Mean preparation asymmetry values at the apical level representing both clinical and proximal views parameters
*Means significance at P <0.05; bars represent standard deviation.


Canal transportation at the middle third level.
Results of transportation at the middle third level (danger zone) are presented in Figure 2. More transportation was found on J-form canals prepared by the Ni–Ti S-files in both views. Statistically significant differences ( P < 0.05) were found between the Ni–Ti K-files and Ni–Ti S-files only in the proximal view of this form of canal. The least transportation was associated with the C-form canals instrumented by Ni–Ti S-files. This parameter was found to be significant ( P < 0.05) between the J-form and C-form groups both in the clinical and proximal views when the preparation was made by Ni–Ti S-files.

Figure 2. Mean asymmetry values at the "danger" zone representing both clinical and proximal parameters.

Mean asymmetry values at the danger zone representing both clinical and proximal parameters
*Means significance at P <0.05; bars represent standard deviation.


Discussion - References.
Discussion.
Comparison of the amount of removed dentine in conjunction with the preparation time represents the efficiency of an instrument. The S-files removed more dentine than the K-type files (Stenman & Spångberg 1990), possibly because the rake angle of the S-file is positive compared to the K-file (Schafer 1997). In this study, the preparation times tended to be shorter for Ni–Ti K-files compared to Ni–Ti S-files in all groups (Table 1). An explanation for this finding is the fact that the Ni–Ti S-files removed significantly more dentine at the most coronal level compared to the Ni–Ti K-files. The circumferential instrumentation of unflared canals requires substantial dentine removal at this level and the more effective the instrument the more dentine is removed at the most coronal level. This dentine removal resulted in a longer preparation time and increased fatigue for the operator.
Procedural accidents such as zip and elbow formation were observed in straight root canals. This surprising result may be explained by the morphology of human root canals. Roots grouped as ‘straight’ do actually have slightly curved canals (Dobo-Nagy et al. 1995). Our conception concerning the relatively high prevalence of procedural accidents in straight canals is discussed in our previous paper (Dobo-Nagy et al. 1997b). In the present study no significant differences were observed between the two instruments in terms of procedural accidents. However, semiquantitative methods for observing the prevalence of perforations, blockage or zip and elbow formation are not adequate for determining fine differences between instruments.
The preparation asymmetry measurement (Dobo- Nagy et al. 1997a,b) is a sensitive quantitative method for determining the transportation of root canals. Using this method the Ni–Ti S-file produced greater transportation at the apical as well as at the danger zone in J-form canals. The differences in transportation between the two instruments in the J-form canal group may be explained by the different designs of the two instruments. The positive rake angle combined with unbalanced preparation of Ni–Ti S-files delivered an increased hour-glass shape in abrupt curvatures. This implies that the Ni–Ti K-files should be chosen for abrupt curvatures in preference to Ni–Ti S-files. Comparison of transportation values according to root canal forms revealed a statistically significant difference between J- and C-form canals prepared with Ni–Ti S-files. This observation may be explained by the increased effectiveness of the Ni–Ti S-files in the coronal part of the canal. This simplified root canal form modified by the instrument itself delivered significantly better results in the C-form canal group prepared with Ni–Ti S-files.

References.

Al-Omari MAO, Dummer PMH, Newcombe RG (1992) Comparison of six endodontic files to prepare simulated root canals. Part 1. International Endodontic Journal 25 , 57-66.
Briseno BM, Sonnabend E (1991) The influence of different root canal instruments on root canal preparation: an in vitro study. International Endodontic Journal 24 , 15-23.
Carvalho LAP, Bonetti I, Borges MAG (1999) A comparison of molar root canal preparation using stainless-steel and nickel-titanium instruments. Journal of Endodontics 25 , 807- 10.
Dob?-Nagy C, Szab? J, Szab? J (1995) A mathematically based classification of root canal curvatures on natural human teeth. Journal of Endodontics 21 , 557-60.
Dob?-Nagy C, Bartha K, Bern?th M, Verdes E, Szab? J (1997a) A comparative study of seven instruments in shaping the root canal in vitro. International Endodontic Journal 30 , 124- 32.
Dob?-Nagy C, Bartha K, Bern?th M, Verdes E, Szab? J (1997b) The effect of root canal morphology on canal shape following instrumentation using different techniques. International Endodontic Journal 30 , 133-40.
Elliott LM, Curtis RV, Pitt Ford TR (1998) Cutting pattern of nickel-titanium files using two preparation techniques. Endodontics and Dental Traumatology 14 , 10-5.
Forsberg J (1992) A method for experimental dental radiography. International Endodontic Journal 25 , 93-6. Gambill JM, Alder M, del Rio CE (1996) Comparison of nickel- titanium and stainless steel hand-file instrumentation using computed tomography. Journal of Endodontics 22 , 369- 75.
Harlan AL, Nicholls JI, Steiner JC (1996) A comparison of curved canal instrumentation using nickel-titanium or stainless steel files with the balanced-force technique . Journal of Endodontics 22 , 410-3.
Mullaney TP (1979) Instrumentation of finely curved canals. Dental Clinics of North America 23 , 575-92.
Schafer E (1997) Root canal instruments for manual use: a review. Endodontics and Dental Traumatology 13 , 51- 64.
Stenmann E, Spangberg LSW (1990) Machining efficiency of endodontic K-files and Hedstrom files. Journal of Endodontics 16 , 375-82.