Journal of Endodontics Research - http://endodonticsjournal.com
Shaping ability of GT Rotary Files in simulated resin root canals
http://endodonticsjournal.com/articles/74/1/Shaping-ability-of-GT-Rotary-Files-in-simulated-resin-root-canals/Page1.html
By JofER editor
Published on 07/10/2002
 
F.L.G. Calberson, C.A.J.G. Deroose, G.M.G. Hommez, H. Raes and R.J.G. DeMoor
Department of Operative Dentistry and Endodontology, Dental School, Ghent University Hospital, Ghent University, Gent, Belgium.
Department of Biology, Ghent University, Gent, Belgium.


Aim.
The aim of this study was to determine the shaping ability of GT Rotary Files in simulated root canals.

Conclusions.
Under the conditions of this study, GT Rotary Files produced acceptable canal shapes. In narrow and curved canals, the length of the straight section of the canal determines the direction of transportation more than the angle of the curve. In the 608 curves, a high incidence of instrument deformation was found when using the 0.04 tapered instruments.

Introduction.
F.L.G. Calberson, C.A.J.G. Deroose, G.M.G. Hommez, H. Raes and R.J.G. DeMoor
Department of Operative Dentistry and Endodontology, Dental School, Ghent University Hospital, Ghent University, Gent, Belgium.
Department of Biology, Ghent University, Gent, Belgium.


Introduction.
The objectives of root canal instrumentation are to clean and shape the canal system(Schilder1974).The ideal preparation for the root canal is a funnel shaped form with the smallest diameter at the apex and the widest diameter at the or ice (Schilder 1974). This is not an easy task in teeth with curved canals and in teeth with complex root canal anatomy.
The funnel shaped form can be achieved either by hand or by mechanical preparation. This optimal shape can be easily provided in straight canals, however, in narrow and curved canals aberrations, such as ledging, zipping, danger zones and canal transportation appear because larger instruments tend to straighten the canal (Esposito & Cunningham1995, Glosson et al.1995).
More flexible files made of nickel-titanium have been effective in minimizing complications in narrow and curved canal preparation (Wu&Wesselink1995,Zmener & Banegas 1996, Thompson & Dummer 1997). In this respect, it has been shown that nickel-titanium instruments have several advantages over stainless steel files such as agreater flexibility due to super elasticity, a shape memory effect and a better resistance to torsional fracture (Walia et al.1988).
Rotary nickel-titanium instruments for the mechanical preparation of root canals are available in various designs. At this time, there is little information available on the shaping ability of GT Rotary Files (Kum et al. 2000). The aim of the present study was, therefore, to investigate the shaping ability of the GT Rotary File System (Dentsply Maillefer, Ballaigues, Switzerland) during preparation in simulated root canals and to record the aberrations that appeared. In this respect, root canals with 408 and 608 curves were produced. The shaping ability of nickel-titanium instruments in canals with a 608 curve has not yet been investigated.

Materials and methods.
Construction of simulated canals.
A total of 40 simulated root canals were made in clear resin blocks (Dummer et al.1991). Annealed silver points size 20 were used as root canal templates. Four different canal types (Fig.1) were made by precurving silverpoints using canal formers. The bent silver points were then checked under magnification (8x) for their alignment to the canal former, and inappropriate points were discarded. Clear spectrophotometer cuvettes were used as moulds to retain the self-polymerizing resin (Stycast 1266, Emerson & Cuming, Westerlo, Belgium) that was poured around the preformed silver points. The finished clear resin blocks were 3.5 cm long.
In all, 40 simulated canals were produced, with either 408 and 608 curves and with a straight section prior to the curve of either 8 or12 mm. The four different canal types are pictured in Fig.1. The angle and radius of the curvature were determined according to Pruett et al. (1997); the radius was 6 mm.

Figure 1. The four different canal types.

The four different canal types

Instruments.
The instruments in the GT Rotary File system (Dentsply Maillefer) feature flat outer edges with a U-file design which prevent self-threading. The files have variable tapers, common tip sizes, radial-landed flutes, maximum flute diameters and non-cutting tips. According to the manufacturer, they also posses the properties of nickel-titanium alloy which allows creation of a tapered funnel around curvatures, whilst keeping the preparation in the canals original position. The system comprises three types of instruments. The first four instruments are the GT Rotary Files with a taper of 6, 8,10 and 12%. The instruments all have the same tip diameter of 0.20 mm. The second four instruments are the GT Rotary Files 0.04 having a 4% taper with a tip diameter ranging from size 20 to size 35. These files are used for the preparation of the apical third and are identical to the ProFile series. The final files are the GT Accessory Files with a 12% taper and a tip diameter of size 35, size 50 and size 70.

Preparation of simulated canals.
All canals were prepared with  GT Rotary instruments using a 128 :1 reduction hand piece (Anthogyr, Endodontic Ni-Ti Contra Angles, Sallanches, France) powered by an electric motor (40 000 rpm). Ten canals of each shape were prepared by the operator to a working length of 16 mm using a constant speed of 312 rpm. The preparation followed the instructions of the manufacturer. The basic method was a‘crown-down/stepback’ method. A new set of instruments was used per canal. The files were wiped off on a gauze to remove resin particles. Irrigation with tap water using disposable syringes was performed after each file. A size15 Flexofile (Dentsply  Maillefer) was used as a patency file. The method for preparation was as follows:
  1. a file with taper 0.12 and tip diameter 20 was used to prepare the first 4 mm of the straight section with a slight in and out movement;
  2. a file with taper 0.10 and tip diameter 20was used to a depth of 8 mm;
  3. a file with taper 0.08 and tip diameter 20was used to a depth of12 mm;
  4. a file with taper 0.06 and tip diameter 20was used to a depth of14 mm;
  5. a file with taper 0.04 and tip diameter 20 was used to the full working length of16 mm;
  6. a file with taper 0.04 and tip diameter 25 was then used to full working length;
  7. a file with taper 0.04 and tip diameter 30 was used to full working length minus 0.5 mm;
  8. a file with taper 0.04 and tip diameter 35 was then used to full working length minus1mm.
During preparation, each resin block was placed in a copper holder, masking the entire canal, to aid handling (Fig. 2). Masking the resin blocks ensured that the process was carried out with purely tactile sensation.

Figure 2. Each resin block was placed in a copper holder, masking the entire root canal, to aid handling during root canal preparation.

Each resin block was placed in a copper holder, masking the entire root canal, to aid handling during root canal preparation

Assessment of canal preparation.
The results of the canal preparations were assessed using a video camera (CCTV Camera, Panasonic WVBL604, Matsushita Industrial Co, Osaka, Japan) connected to a light microscope (Reichert-Jung Polyvar, Reichert optische werke AG, Wien, Austria) and attached to a Pentium III computer with image analysis software (Interactive Bild-analyse System (IBAS), Kontron Electronic Gmbh, Germany). Measurements were made on superimposed pre- and post-operative digitized images. In order to achieve a standardized position of the resin blocks under the microscope, a holder was made in which the resin blocks could be placed and repositioned in exactly the same position. Reference points were recorded by means of the microscope’s nonius scale. At the experimental magnification, it was impossible to visualize the entire canal. One image on screen corresponded to 2.3 mm of the real canal length. Depending on the canal type,8-10 images were needed to assemble the entire canal. Both X and Y coordinates on the microscope’s nonius scale were recorded for each image, allowing repositioning and reproduction of the pictures at any given moment (i.e. pre- and postoperative).
For each resin block, the captured images, representing parts of the canal, were precisely aligned to form a picture of the entire canal. The centre of the original canal path was calculated by the software.
After preparation with the GT Rotary Files the simulated canals were viewed again in the microscope. For each resin block, setting the previously recorded X and Y coordinates of the original canal, corresponding images of the post-operative canal were captured and aligned to forma picture of the entire canal after instrumentation. Both pre- and postoperative images were then superimposed.
At this stage, five points were determined on each central canal path, for measuring the canal width, using a modification of the method described by Alodeh & Dummer (1989) (Fig. 3):
  • position1: the canal orifice (O);
  • position 2: a point half-way from the beginning of the curve to the orifice (HO);
  • position 3: the beginning of the curve (BC);
  • position 4: the apex of the curve of the original canal (AC), determined by the intersection of two lines (one along the coronal aspect of the central line, and the second along the apical portion of the central line);
  • position 5: end point of preparation (EP).
All measurements were carried out perpendicular to the axis of the original central canal path to the nearest 0.001mm, using the image analysis software.
The canal aberrations to be scored were zips and elbows, ledges, perforations, and danger zones (Alodeh & Dummer1989) as well as the‘outer widening’ (Bryant et al. 1999). In this respect, a representative composite print of superimposed pre- and postoperative canals with apical zip and elbow is shown in Fig. 4.

Figure 3. Composite print of a type II canal outlining the 5 positions of measurement. The white region defines the image of the canal before preparation, the grey region defines the canal after preparation.

Composite print of a type II canal outlining the 5 positions of measurement

Figure 4. Composite image of the simulated resin canals (type IV) with apical zip and elbow in the GT Rotary File technique. The white region defines the image of the canal after the preparation, and the black region defines the canal before preparation.

The white region defines the image of the canal after the preparation, and the black region defines the canal before preparation

Recording, storage, and analysis of data.
All data were stored on PC from the image processing software directly to a database file. Following error and range checks, the data were analyzed using SPSS, a statistical analysis program. Differences at the five measuring points between the mean total widths, the mean inner widths and the mean outer widths were statistically analyzed using anova. Statistical analysis of the number of canals transported towards the inner and outer aspect of the curve was done by the Kruskal-Wallis Test.

Results.
Because of the presence of two separated instruments (i.e. two 0.04/30 instruments, the one in a type II canal and the other in a type IV canal), the results are based on the analysis of 38 canals.

Width measurements and transportation.
Table 1 shows the mean total widths of the canals by shape. Tables 2 and 3 show, respectively, the mean right (outer) width and the mean left (inner) width of the canals by shape. There were statistically significant differences (P < 0.001) in the total width (Table 1) of the canals between the various canal shapes at the apex of the curve, the beginning of the curve and half-way to the orifice in the straight section. There were statistically significant differences (P = 0.001) for the amount of resin removed from the outer aspect of the curve (Table 2) at the apex of the curve, the beginning of the curve and half-way to the orifice in the straight section; and for the amount of resin removed from the inner aspect of the curve (Table 3) at all five measuring points (orifice, apex of the curve and endpoint (P < 0.05); halfway the orifice (P < 0.001); beginning of the curve (P = 0.001)).
Table 4 shows the direction of transportation at the specific positions along the canal length. Transportation was towards the inner aspect of the canal in canals with straight sections of 12 mm regardless the curve angle (types I and III); towards the outer aspect in canals with straight sections of 8 mm and 408 curves (type II) at all ¢five measuring points, and at the apex of the curve, the beginning of the curve and half-way to the orifice in the straight section when the curve was 608 (type IV). The occurrence of ‘outer widening’, i.e. an almost exclusive removal of resin on the outer aspect of the canal and associated with a narrower region situated more coronally was seen in three of the 10 type III canals and in three of the nine type IV canals.

Table 1. Mean total widths (mm) of canals by canal shape.

Mean total widths of canals by canal shape

Table 2. Mean outer width measurements (mm) of canals by canal shape.

Mean outer width measurements of canals by canal shape

Table 3. Mean inner width measurements (mm) of canals by canal shape.

Mean inner width measurements of canals by canal shape

Table 4. Number of canals transported towards the inner and outer aspect of the curve by canal shape.

Mean outer width measurements of canals by canal shape

Table 5. Incidence of canal aberrations and instrument failures by canal shape.

Incidence of canal aberrations and instrument failures by canal shape

Canal aberrations.
Table 5 shows the incidence of canal aberrations in relation to the canal type. A zip was encountered in eight canals (canal type I: 5; type III: 1; type IV: 2). There were no zips in type II canals. There was only one ledge in a type I canal. There were no perforations nor danger zones (i.e. excessive removal of resin on the inner curve).

Instrument evaluation.
Instrument failure is characterized either by fracture or by deformation. A total of nine instruments deformed during preparation (five in a type IV canal and four in a type III canal) and two fractured. The fracture of these two instruments, both 0.04/30, occurred at the tip of the instrument and beyond the apex of the curve (the one in a type II canal and the other in a type IV canal and in both canal types the beginning of the curve starts at 8 mm from the orifice).The deformations were see at the tip (5x) and at the mid-portion (4x) of the instruments with 0.04 tapers.

Discussion - References.
Discussion.
The maintenance of canal curvature and the creation of a funnel shaped canal form with the smallest diameter at the apex and the widest diameter at the orifice are the objectives during instrumentation of root canals (Schilder & Yee 1984). The problem of straightening occurs mostly in severely curved canals and at the apex of the canal (Weine et al.1975). In recent years, a great number of reports described the advantages of nickel-titanium rotary instruments. These instruments have the potential to prepare root canals rapidly and safely to produce relatively few aberrations during the root canal preparation. Care, however, should be taken when canals with short curves beginning near the end-point are to be prepared (Bryant et al. 1999).
The aim of this study was to assess the shaping ability of GT Rotary Files in simulated root canals with a severe curve. The preparation technique that was used was a crown-down/stepback technique, as advocated by the manufacturer. To assess instrumentation of curved canals, clear resin blocks were used in this study. These were chosen because shape, size, taper, and curvature of the experimental canals are standardized. The credibility of resin blocks as an ideal experimental model for the analysis of endodontic preparation and preparation techniques has been validated by Weine et al. (1975) and Dummer et al. (1991). Because of slight differences in hardness between dentine and the experimental resin, care should be taken, however, in extrapolating the results to the clinical situation. Never theless, the use of simulated canals in resin blocks results in the opportunity to standardize the research method and to exclude parameters that could influence the preparation outcome.
The determination of the degree of curvature of root canals was based on data according to Schneider (1971), i.e. the degree of canal curvature is determined by only one parameter, the angle formed by the intersection of two lines. The first line is drawn parallel to the long axis of the canal, and the second line runs from the apical foramen to the point wherein the canal begins to leave the long axis of the canal. This method was refined by Alodeh & Dummer (1989) who added the radius of the curve as a second parameter in defining the degree of root curvature.
Nickel-titanium files have already shown their efficiency in shaping the root canal. Their flexibility assumes that they could be useful during preparation of curved canals by keeping the preparation path centred, and by creating a tapered preparation thanks to the specifically tapered design of consequent instruments. Aberrations of the root canal, still occur, albeit to a lesser degree than in non-mechanical instrumentation (Kum et al. 2000). Additional problems, such as instrument deformation and breakage still occur, especially in curved canals. The question remains as to what critical degree of curvature a nickel-titanium file can be used safely. Some manufacturers advise not to use rotary instruments in root canals with curves exceeding 608. The present data show that the presence of a 608 curve does not necessarily result in more aberrations than in canals with a 408 curve. In a study comparing the use of ProFile rotary nickel-titanium instruments Bryant et al. (1998) showed that aberrations occurred more often in canals where the curve began 12 mm from the orifice. In the present study, a similar finding was observed. When the number of separated or deformed instruments was compared, deformation of 0.04 tapered instruments occurred more frequently in a 608 curved canal. Instrument fracture was seen in 0.04/30 instruments in canals with a straight section of 8 mm regardless of the angle of curve. Bryant et al. (1999) stated in this respect when using 0.04 and 0.06 ProFiles that the use of 0.06 taper instruments in the crown-down technique appeared to be useful and was recommended. The crown-down approach with the GT Rotary Files with a taper of 6, 8, 10 and 12% is also highly recommended. Great care, however, should be taken in canals with 608 curves as instrument deformation is high and may result in consequent instrument fracture. Torque control as a safety measure has, therefore, been advocated by the manufacturer, although Yared et al. (2001) demonstrated that there was no difference with respect to the incidence of instrument failure between no-torque and high and low torque motors.
Canal types I and III showed a transportation towards the inner aspect of the canal, whereas transportation in canal types II and IV was to the outer aspect. Thanks to the direct visualization through the resin blocks during preparation it was seen that the canal aberrations especially became clear when enlarging the endpoint of preparation to a size 30 or 35. These size sare more rigid than the smaller ones, and tend to straighten the canal. This suggests that in canals with short acute curvatures, instrumentation of the apical part with GT Rotary Files should better not exceed the size 25 in narrow canals in order to obtain a tapered shape. These findings agree with those of Bryant et al. (1998) in their research on ProFile 0.04 and 0.06 tapered instruments. In this respect, it must also be said that there is no difference in design between the GT Rotary Files 0.04 and Pro-Files 0.04.
The phenomenon of ‘outer widening’ (Bryant et al. 1999) was only seen in a limited number of resin canals with a 608 curve. The use of the more tapered instruments initially to open the orifice allowed the 0.04 series to pass more easily to the end-point and to remain centered in the canal. The fire fore, a strict crown-down approach to avoid stress on instruments by early opening of the coronal part of the root canal when using nickel-titanium rotary instruments is essential.

References.

AlodehMHA, Dummer PMH (1989) Acomparison of the ability of   K-files and Hedstrom files to shape simulated root canals in resin blocks.   International Endodontic Journal 22, 226-35.
  Bryant ST, Dummer PMH, Pitoni C, Bourba M, Moghal S (1999) Shaping ability   of .04 and .06 taper ProFile rotary nickel-titanium instruments in simulated   root canals. International Endodontic Journal 32, 155-64.
  Bryant ST,Thompson SA, Al-Omari MAO, Dummer PMH (1998) Shaping ability of   ProFile rotary nickel-titanium instrumens with ISO sized tips in simulated root   canals. Part 2. International Endodontic Journal 31, 282-9.
  Dummer PMH, Alodeh MHA, Al-Omari MAO (1991) A method for the construction   of simulated canals in clear resin blocks. International Endodontic Journal   24, 63-6.
  Esposito PT, Cunningham CJ (1995) A comparison of canal preparation with   nickel-titanium and stainless steel instruments. Journal of Endodontics   21, 173-6.
  Glosson CR, Haller RH, Dove SB, DelRio CE (1995) A comparison of root canal   preparations using Ni-Ti hand, Ni-Ti engine-driven and K-Flex endodontic instruments.   Journal of Endodontics 21, 146-51.
  Kum KY, Spangberg L, Cha BY, Il-Young J, Seung-Jong L, Chan- Young L (2000)   Shapingability of three ProFile Rotary instrumentation techniques in simulated   resin root canals. Journal of Endodontics 26, 719-23.
  Pruett JP, Clement DJ, Carnes DL (1997) Cyclic fatigue testing of nickel-titanium   endodontic instruments. Journal of Endodontics 23,77-85.
  Schilder H (1974) Cleaning and shaping the root canal. Dental Clinics   of North America 18, 269-96.
  Schilder H,Yee FS (1984) Canal debridement and desinfection. In: Cohen,   S, Burns, RC, eds. Pathwayso f the Pulp, 3rd edn. St. Louis: The CV Mosby Company,   p.175.
  Schneider SW (1971) A comparison of canal preparations in straight and curved   canals. Oral Surgery 32, 271-5.
  Thompson SA, Dummer PMH (1997) Shaping ability of ProFile .04 taper series   29 rotary nickel-titanium instruments in simulated root canals. Part1. International   Endodontic Journal 30, 1-7.
  Walia H, Brantley WA, Gerstein H (1988) An initial investigation of the bending   and torsional properties of Nitinol root canal files. Journal of Endodontics   14, 346-57.
  Weine FS, Kelly RF, Lio PJ (1975) The effect of preparation procedures on   original canal shape and on apical foramen shape. Journal of Endodontics   1, 225-62.
  Wu MK,Wesselink PR (1995) Efficacy of three techniques in cleaning the apicalportion   of curved canals. Oral Surgery Oral Medicine Oral Pathology 79,492-6.
  Yared GM, Bou Dagher FE, Machtou P (2001) Failure of ProFile instruments   used with high and low torque motors. International Endodontic Journal 34,   471-5.
  Zmener O, Banegas G (1996) Comparison of three instrumentation techniques   in the preparation of simulated root canals. International Endodontic Journal   29, 315-9.